Usage: pdb2reaction scan2d [OPTIONS]
2D distance scan with harmonic restraints.
Options:
-v, --verbose LEVEL Console verbosity 0-3 (default 2). 0=silent;
1=milestones only; 2=+optimizer cycle tables,
per-stage timing, VRAM, deliverable paths;
3=everything (full config blocks, per-file
paths, DEBUG logging). [0<=x<=3]
--help-advanced Show all options (including advanced settings)
and exit.
-i, --input FILE Input structure file (.pdb, .cif, .mmcif,
.xyz, _trj.xyz, ...). [required]
-s, --scan-lists TEXT Scan targets: inline Python literal or a
YAML/JSON spec file path. scan2d expects
EXACTLY 2 quadruples (i, j, low, high) — one
per scanned bond axis — e.g.
'[(12,45,1.30,3.10),(10,55,1.20,3.20)]'. Atom
indices may also be strings like 'CE SAM 216';
use positional
CHAIN:RESNAME:RESSEQ[ICODE]:ATOM when chain
qualification is needed. Step count per axis
is set via --max-step-size, NOT inside the
tuple (scan2d does not accept a 5th element;
the scan command's 3-tuple (i, j, target) form
is rejected here too). [required]
-q, --charge INTEGER Total charge. Required for non-.gjf inputs
unless --ligand-charge is provided (PDB/mmCIF
inputs or XYZ/GJF with --ref-pdb).
--workers INTEGER MLIP predictor workers; >1 spawns a parallel
predictor. NOTE: with UMA, workers>1 plus an
explicit Analytical Hessian request is an
error; use workers=1 or FiniteDifference.
[default: 1]
--workers-per-node INTEGER Workers per node when using a parallel MLIP
predictor (workers>1). [default: 1]
-l, --ligand-charge TEXT Total charge or per-resname mapping (e.g.,
GPP:-3,SAM:1) used to derive charge when -q is
omitted (requires PDB/mmCIF input or --ref-
pdb).
-m, --multiplicity INTEGER Spin multiplicity (2S+1). [default: (1)]
--one-based / --zero-based Interpret (i,j) indices in --scan-lists as
1-based or 0-based. [default: one-based]
--max-step-size FLOAT Maximum step size per scanned distance [Å].
[default: 0.2]
--bias-k FLOAT Harmonic well strength k [eV/Å^2]. YAML bias.k
applies when this option is omitted; explicit
CLI wins. [default: (300.0)]
--relax-max-cycles INTEGER RANGE
Maximum optimizer cycles per grid relaxation.
An explicitly provided value overrides YAML
opt.max_cycles. [default: (100000); x>=1]
--opt-mode [grad|hess] Relaxation mode: grad (=LBFGS) or hess (=RFO).
[default: grad]
--freeze-links / --no-freeze-links
Freeze parent atoms of cap hydrogens
(PDB/mmCIF input or XYZ/GJF with --ref-pdb).
[default: freeze-links]
--freeze-atoms TEXT Comma-separated 1-based atom indices to freeze
(e.g., '1,3,5').
--dump / --no-dump Write inner scan trajectories per d1-step as
TRJ under result_scan2d/grid/. [default: no-
dump]
--convert-files / --no-convert-files
Convert XYZ/TRJ outputs into PDB/CIF/GJF
companions based on the input
topology/template. [default: convert-files]
--ref-pdb FILE Reference PDB/mmCIF topology to use when the
input is XYZ/GJF (keeps XYZ coordinates).
-o, --out-dir TEXT Base output directory. [default:
./result_scan2d/]
--thresh [gau_loose|gau|gau_tight|gau_vtight|baker|never]
Convergence preset (gau_loose|gau|gau_tight|ga
u_vtight|baker|never). [default: (baker)]
--config FILE Base YAML configuration file applied before
explicit CLI options.
--preopt / --no-preopt Pre-optimize the initial structure without
bias before the scan. [default: no-preopt]
-b, --backend [uma|orb|mace|aimnet2]
MLIP backend. [default: uma]
--solvent TEXT Experimental, computationally expensive xTB
solvent delta correction. Examples: water,
methanol, acetonitrile, dmso, thf, toluene.
'none' disables it. [default: none]
--solvent-model [alpb|cpcmx] xTB solvent model. [default: alpb]
--baseline [min|first] Reference for relative energy (kcal/mol):
'min' or 'first' (i=0,j=0). [default: min]
--zmin FLOAT Lower bound of color scale for plots
(kcal/mol). [default: (the surface minimum)]
--zmax FLOAT Upper bound of color scale for plots
(kcal/mol). [default: (the surface maximum)]
--print-parsed / --no-print-parsed
Print parsed scan targets after resolving
--scan-lists. [default: no-print-parsed]
--out-json / --no-out-json Write machine-readable result.json to out_dir.
[default: no-out-json]
--dry-run / --no-dry-run Resolve and validate options (input,
charge/spin parity, --scan-lists parse) and
print the planned scan, then exit without
running any optimization. [default: no-dry-
run]
--coord-type [cart|redund|dlc|tric]
Optimization coordinate system
(cart|redund|dlc|tric). [default: (cart)]
--print-every INTEGER RANGE Print optimizer status every N cycles.
[default: (100); x>=1]
--precision [fp32|fp64] MLIP backend precision: fp32 or fp64. Unset
defaults per backend (uma: fp32; orb, mace:
fp64). Routed to backend-specific kwargs (UMA
precision / ORB precision / MACE
default_dtype). aimnet2: fp32 no-op; fp64
rejected. [default: (per backend: uma fp32;
orb, mace fp64)]
--backend-model TEXT Model variant for the selected --backend (e.g.
uma-s-1p2 / uma-m-1p1 for uma,
orb_v3_conservative_omol for orb, MACE-OMOL-0
/ off:small for mace). [default: (the
selected backend's own model)]
--calc-file FILE Python file exposing get_calculator(...) -> an
ASE Calculator, used as the energy/gradient
backend (overrides --backend). Couples GFN-xTB
/ DFTB+ / any ASE engine. See --calc-file-
func-name.
--calc-file-func-name TEXT Name of the callable in --calc-file that
returns an ASE Calculator (or a module-level
Calculator instance). CLI overrides config
YAML; otherwise defaults to get_calculator.
[default: (get_calculator)]
--deterministic / --no-deterministic
Request strict same-stack PyTorch determinism
(deterministic algorithms + index_reduce_
shim). Slower; raises for detected unsupported
ops; custom calculators are outside its scope.
[default: no-deterministic]
--allow-charge-mult-mismatch Skip the cluster charge/multiplicity electron-
parity check (logs that it was skipped). Open-
shell clusters need a matching multiplicity
instead; use this only for an intentionally
nonstandard electron count.
-h, --help Show this message and exit.